back

DETAILS – WATER TREATMENT PLANTS


RISKS IN WATER – WHAT CAN HAPPEN?

Salts (hardness constituents) are dissolved in all natural water. The type and concentration of water constituents in drinking water varies depending on the origin of the water and the way it is obtained.

The water constituents can cause the following problems during the operation of cleaning plants:

Hardness components (calcium and magnesium salts)

Formation of deposits in the washing equipment, lime deposits due to calcium and magnesium hydrogen carbonate, clogging of the washing nozzles, corrosion potential and or visible residues on the surface of the washed goods.

The customer’s water quality has an influence on the surface quality of the cleaned wash goods, the performance as well as on lime or mineral deposits in the system. The decisive factors are the raw water hardness and the mineral salt content. For trouble-free operation we recommend:
Water quality Standard plants (crate, pallet cleaning, etc.) Water hardness max. 5° German hardness Conductivity max. 500 MicroS / cm2
Rinsing water quality Chocolate mould cleaning plants (100% stain-free) Water hardness max. 1 – 3° German hardness Conductivity max. 20 MicroS / cm2

WATER SOFTENING – SOFT WATER

A water softening system provides soft water and prevents lime deposits. The following applies: The harder the water, the higher the risk of lime precipitation. The conductivity of the water after softening is max 500 MicroSiemens. This guarantees trouble-free operation of the washing systems.

OPERATION OF REVERSE OSMOSIS – OSMOSIS WATER

An osmosis plant (full demineralization ) frees the tap water from all minerals. The conductivity of the water after demineralization is max 20 MicroSiemens. This guarantees an absolutely spotless rinsing result on the washing machines.

Softening plant

Osmosis plant

Soft water

Soft water

Osmosis water

Osmosis water

Plant type

Capacity

German hardness

Conductivity 

German hardness

Conductivity

WA – 250

250 L/Std

5-7  °DH 

500 Micro/Siemens

0-1 °DH 

20 Micro/Siemens

WA – 500

500 L/Std

5-7  °DH 

500 Micro/Siemens

0-1 °DH 

20 Micro/Siemens

WA – 800

800 L/Std

5-7  °DH 

500 Micro/Siemens

0-1 °DH 

20 Micro/Siemens

Hildebrand Industry AG

Marksteinstrasse 2
8552 Felben-Wellhausen
SWITZERLAND
hildebrandindustry.ch
sales@hildebrandindustry.ch
service@hildebrandindustry.ch

Imprint | Data Privacy
Tel. + 41 (0) 52 368 45 15
Privacy Settings
We use cookies to enhance your experience while using our website. If you are using our Services via a browser you can restrict, block or remove cookies through your web browser settings. We also use content and scripts from third parties that may use tracking technologies. You can selectively provide your consent below to allow such third party embeds. For complete information about the cookies we use, data we collect and how we process them, please check our Privacy Policy
Youtube
Consent to display content from - Youtube
Vimeo
Consent to display content from - Vimeo
Google Maps
Consent to display content from - Google